pHASE Acid Neutralization

 

Battery Acid Neutralization Systems

System Features

  • Skid Mounted
  • Turnkey Construction
  • Minimal Installation Time
  • Completely Automated
  • NEMA 4X, UL 508
  • State of the Art Controls
  • Bi-Directional pH Control.
  • Will handle concentrated acid and wastes acids of any source.
  • High Temperature Design with process cooling.

The neutralization of waste acids such as battery acid can be quite hazardous if not performed properly and cautiously. Battery acid, the electrolyte in all lead / acid cell batteries, is sulfuric acid (H2SO4) at a concentration of between 15 and 35%. At this concentration sulfuric acid is very dangerous and will react with almost everything especially organic material including human flesh.

All acids must be neutralized before disposed of and battery acid, although very dangerous, can be safely neutralized yielding harmless salts. The heat liberated from the neutralization of sulfuric acid (battery acid) is very high and can result in a temperature rise of over 1000C (2120F). In the lab we have measured temperatures as high as 2500F.

If extreme care is not exercised the energy released during the neutralization cycle can be explosive, and, at a minimum, be sufficient to melt all thermoplastics. Digital Analysis utilizes a unique process for the neutralization of battery acid one in which the rate of reaction is constantly controlled and is limited by temperature. As the temperature of the process rises and begins to approach a field defined setpoint the rate of reaction is slowed or even halted as is dictated by the rate of rise. Additionally cooling water can be added in the event that the temperature rises beyond a safe level.

Our battery acid neutralizers can be used to neutralize any concentrated acid not just battery acid. These systems are also very well equipped to neutralize almost any concentration of waste acids and bases.

Our waste acid neutralization systems are based upon our standard pHASE product line and are rated in gallons per day (GPD) as opposed to GPM (see chart below).

Standard Materials of Construction*

*Alternate materials of construction available.

Waste Acid Neutralization System

Waste Acid Neutralization System with temperature limiting and cold water quench

Optional Equipment

  • Influent Equalization
  • Influent / Effluent Lift Stations
  • Final Effluent Monitoring
  • Effluent Sampling
  • SCADA System Monitoring
  • Duplex Systems for Redundancy
  • Bulk Chemical Delivery
  • Explosion Proof Design
MODEL Average Flow* (GPH) Max Peak Flow* (GPH) Treatment Tank Volume (Gallons) Skid Dimensions
pH05 5 10 155 40" x 40" x 60"(H)
pH10 10 15 360 48" x 48" x 60"(H)
pH15 15 25 475 34" x 65" x 60"(H)
pH20 20 60 475 34" x 65" x 60"(H)
pH30 30 90 660 44" x 85" x 62"(H)
pH40 40 120 660 44" x 85" x 62"(H)
pH60 60 180 660 44" x 85" x 62"(H)

*Average Flow = Average 60 minute flow rate.
*Peak Flow = Peak flow rate for less than 5 minutes.

Note: pH Systems with flows in excess of 10,000 GPM are available